A long repair list, broken into stages you can plan
Get a staged plan
Tell us what the inspection found, or that you have not had one yet, and what you plan for the fireplace wall.
A staged plan, in order
A Level 2 report with eight findings can read like one huge bill. Most of the time it is three smaller jobs. We sort every finding into a stage by what happens if it waits, and quote each stage on its own so you can approve one and plan the next.
- Stage 1, before the next fire: cracked or missing flue tiles, a gas unit venting badly, a firebox with open joints, a damper that cannot open fully.
- Stage 2, before the rains: an open flue with no cap, failed flashing, a cracked crown, a missing cricket behind a wide chimney.
- Stage 3, with the remodel: the face, the mantel and hearth clearances, a gas insert to replace the wood fire, waterproofing the brick.
Stage 1: nothing burns until it is done
These are the findings that make the fireplace unsafe to use. A cracked flue lets heat and exhaust reach framing. A gas unit with a broken vent can spill exhaust into the room. Open firebox joints let heat into the wall. Until these are fixed, the fireplace stays off.
Some stage 1 items lead to a choice. A badly cracked clay flue can be relined, or the wood fire can be replaced with a gas insert that brings its own liner. For many Carson owners already planning a new fireplace wall, the insert answers stage 1 and stage 3 at once. Relining on its own is quoted in writing after the camera footage is read.
Stage 2: stop the water
Water does slow damage: it rusts dampers, rots the wood around the chimney, and stains the wall that the new finish will cover. Winter storms are when it shows. A cricket, new flashing and a cap are the usual fixes. The cricket and flashing have a price below, and the cap is quoted after we measure. Crown work is quoted in writing once we have seen the top of the chimney.
Doing stage 2 before stage 3 matters. Stone and plaster over a wet wall will mark within a season.
Stage 3: the finish and the clearances
The last stage is the part you see: the surround, the mantel and the hearth. Findings here are often clearance problems, a mantel too close to the opening or a hearth too short in front of it, and they are cleanest to fix as part of the remodel rather than patched. This stage can wait for your budget and your design, as long as the fireplace is not used with a known clearance problem.
Prices for the usual fixes
These are the fixes we price on the site. They cover most stage 2 items and the insert option in stage 1.
- Camera inspection that sets the stages
- $410
- Water entry traced and stopped
- $590 to $3,500
- Roof diverter behind a wide chimney
- $470 to $1,060
- Diverter plus all new metal at the roof line
- $705 to $1,750
- Sealed gas insert inside the old firebox
- $2,950 to $5,900
- Stainless flue cap, fitted
- Quoted after we measure
Crown, liner, damper, chase top and flashing on its own are quoted in writing after we have seen the chimney.
Questions about staged repairs
Can I use the fireplace between stages?
Once stage 1 is done, usually yes. Stage 2 and stage 3 items do not stop a fire unless the report says so for a specific finding.
I failed an inspection from another company. Can you plan from their report?
Yes. Send us the findings and we will sort them into stages. Some items may need our own look before we can quote them in writing.
Is a gas insert really a repair?
It can be. If the flue is cracked and you would rather have gas, the insert brings its own liner and replaces the part that failed. It is priced at $2,950 to $5,900 installed.
Do I need a permit?
Gas work, new vents and some rebuilds can need a city permit. We tell you on the quote which items do.
Can the stages be done together?
Yes. Many owners combine stage 2 with the remodel. The quote shows each stage separately so you can choose.
Turn the report into a plan
Describe what the inspection found through our contact page, and we will send back the stages with the prices we list and a written quote for the rest.